C613-50631-01 Rev A Command Reference for IE340 Series 534
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY INPUT-ALARM ALARM-POSITION
alarm facility input-alarm alarm-position
Overview Use this command to specify whether an alarm occurs when the input contact
opens or closes.
Then use the commands alarm facility input-alarm led and alarm facility
input-alarm relay to specify whether the alarm triggers an LED or a relay.
Syntax
alarm facility input-alarm 1 alarm-position {open|close}
Default Open
Mode Global Configuration
Example To trigger the alarm relay when the input contact closes, use the commands:
awplus# configure terminal
awplus(config)# alarm facility input-alarm 1 alarm-position
close
awplus(config)# alarm facility input-alarm 1 relay
To return to the default state of open, use the commands:
awplus# configure terminal
awplus(config)# alarm facility input-alarm 1 alarm-position
open
Related
commands
alarm facility input-alarm led
alarm facility input-alarm relay
show alarm facility settings
Command
changes
Version 5.4.9-1.1: input-member parameter added on IE510-28GSX switches
Parameter Description
input-alarm 1 The input contact number. These
switches have one input contact, so
this must be 1.
open An alarm will be triggered when the
input contact opens
close An alarm will be triggered when the
input contact closes