C613-50631-01 Rev A Command Reference for IE340 Series 531
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY EPSR RELAY
alarm facility epsr relay
Overview Use this command to trigger an alarm relay if EPSR detects that a link has gone
down.
This will activate the device that you have connected to the switch’s relay output
(for example, you could connect a buzzer to the relay output).
Use the no variant of this command to remove this alarm.
Syntax
alarm facility epsr relay
no alarm facility epsr relay
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use an alarm to flash the fault LED, by using the command alarm
facility epsr led.
Example To trigger the alarm relay if EPSR indicates that a link has gone down, use the
commands:
awplus# configure terminal
awplus(config)# alarm facility epsr relay
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility epsr relay
Related
commands
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches