C613-50631-01 Rev A Command Reference for IE340 Series 3400
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
TRIGGER COMMANDS
TYPE
TIME
type time
Overview This command configures a trigger that activates at a specified time of day.
Syntax
type time <hh:mm>
Mode Trigger Configuration
Usage A combined limit of 10 triggers of the type time and type periodic can be
configured. If you attempt to add more than 10 triggers the following error
message is displayed:
Example To configure trigger 86 to activate at 15:53, use the following commands:
awplus# configure terminal
awplus(config)# trigger 86
awplus(config-trigger)# type time 15:53
Related
commands
show trigger
trigger
Parameter Description
<hh:mm> The time to activate the trigger.
% Cannot configure more than 10 triggers with the type time or 