C613-50631-01 Rev A Command Reference for IE340 Series 3470
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
MODBUS COMMANDS
SCADA
MODBUS TCP SERVER
scada modbus tcp server
Overview Use this command to enable MODBUS TCP server on a device.
Use the no variant of this command to disable MODBUS TCP.
Syntax
scada modbus tcp server
no scada modbus tcp server
Default Disabled
Mode Global Configuration
Example To enable the MODBUS TCP server, use the following commands:
awplus# configure terminal
awplus(config)# scada modbus tcp server
Related
commands
scada modbus tcp server port
scada modbus tcp server connection
clear scada modbus tcp server connection
clear scada modbus tcp server statistics
show scada modbus tcp server connections
Command
changes
Version 5.4.8-2.1: command added
Version 5.4.9-0.1: MODBUS support added for x930, x950 series