ALARM MONITORING COMMANDS
ALARM
FACILITY UFO LED
alarm facility ufo led
Overview Use this command to make the fault LED flash if one or more UFO VLANs are
isolated and cannot forward traffic.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility ufo led
no alarm facility ufo led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility ufo relay.
Example To flash the LED if one or more UFO VLANs are isolated and cannot forward traffic,
use the commands:
awplus# configure terminal
awplus(config)# alarm facility ufo led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility ufo led
Related
commands
alarm facility ufo relay
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches