C613-50631-01 Rev A Command Reference for IE340 Series 3156
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
PRECISION TIME PROTOCOL (PTP) AND TRANSPARENT CLOCK COMMANDS
CLOCK
-PORT
clock-port
Overview Use this command to associate the port with the clock and enable the required PTP
functionality for 1588v2 packets entering and leaving this port. For the transparent
clock, this specifically means modification of the Correction Factor to reflect the
residence time in the bridge.
Use the no variant of this command to remove the port from the clock and disable
modification of the Correction Factor.
Syntax
clock-port
no clock-port
Default Ports are unassociated and disabled with the clock by default.
Mode Interface Configuration (port)
Example To configure the clock-port on port1.0.1, use the following commands:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# clock-port
To remove port1.0.1 from the clock and disable modification of the Correction
Factor, use the following commands:
awplus# configure terminal
awplus(config)# interface port1.0.1
awplus(config-if)# no clock-port
Related
commands
ptp global
ptp-clk
show ptp data transparent
show ptp port
Command
changes
Version 5.4.7-0.1: command added
Version 5.4.8-0.2: added to x230, x550 series products