C613-50631-01 Rev A Command Reference for IE340 Series 2306
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
AUTHENTICATION COMMANDS
AUTH
-WEB-SERVER PING-POLL TIMEOUT
auth-web-server ping-poll timeout
Overview This command modifies the ping poll timeout parameter for the
Web-Authentication feature. The timeout parameter specifies the time in seconds
to wait for a response to a ping packet.
Use the no variant of this command to reset the timeout of ping polling to the
default (1 second).
Syntax
auth-web-server ping-poll timeout <1-30>
no auth-web-server ping-poll timeout
Default The default timeout for ping polling is 1 second.
Mode Global Configuration
Examples To set the timeout of ping polling to 2 seconds, use the command:
awplus# configure terminal
awplus(config)# auth-web-server ping-poll timeout 2
To set the timeout of ping polling to the default (1 second), use the command:
awplus# configure terminal
awplus(config)# no auth-web-server ping-poll timeout
Validation
Commands
show auth
show auth-web-server
show running-config
Parameter Description
<1-30> Seconds.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals