C613-50631-01 Rev A Command Reference for IE340 Series 555
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
SHOW
ALARM FACILITY SETTINGS
show alarm facility settings
Overview Use this command to see whether an LED flashes or a relay is turned on if a certain
alarm occurs. The output also includes the alarm position for each contact input.
Syntax
show alarm facility settings
Mode User Exec and Privileged Exec
Example To display all the alarm settings on a switch, use the following command:
awplus# show alarm facility settings
Output Figure 14-1: Example output from show alarm facility settings
Related
commands
show alarm facility status
Command
changes
Version 5.4.9-1.1: command syntax changed from show alarm settings to show
alarm facility settings
awplus#show alarm facility settings
Global alarms:
Alarm ID Outputs - L: LED, R: Relay
-----------------------------------------------------------------
EPSR - -
Loop detect - -
G8032 - -
UFO - -
Per stack member alarms:
Alarm ID Outputs - L: LED, R: Relay
-----------------------------------------------------------------
External PSU 1 L
External PSU 2 L
External contact input 1 -
Link down port1.0.1 R1
Link down port1.0.2 -
Link down port1.0.3 -
Link down port1.0.4 -
...
Temperature - -
Alarm ID Alarm position
---------------------------------------------------
External contact input 1 Open