C613-50631-01 Rev A Command Reference for IE340 Series 434
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LOGGING COMMANDS
LOG
EMAIL (FILTER)
log email (filter)
Overview This command creates a filter to select messages to be sent to an email address.
Selection can be based on the priority/ severity of the message, the program that
generated the message, the logging facility used, a sub-string within the message
or a combination of some or all of these.
The no variant of this command configures the device to no longer send log
messages to a specified email address. All configuration relating to this log target
will be removed.
Syntax
log email <email-address> [level <level>] [program
<program-name>] [facility <facility>] [msgtext <text-string>]
no log email <email-address> [level <level>] [program
<program-name>] [facility <facility>] [msgtext <text-string>]
Parameter Description
<email-
address>
The email address to send logging messages to
level Filter messages by severity level.
<level> The minimum severity of message to send. The level can be specified as one of the following
numbers or level names, where 0 is the highest severity and 7 is the lowest severity:
0|emergencies System is unusable
1|alerts Action must be taken immediately
2|critical Critical conditions
3|errors Error conditions
4|warnings Warning conditions
5|notices Normal, but significant, conditions
6|informational Informational messages
7|debugging Debug-level messages
program Filter messages by program. Include messages from a specified program.
<program-
name>
The name of a program to log messages from. You can enter either one of the following
predefined program names (depending on your device model), or another program name
that you find in the log output. The pre-defined names are not case sensitive but other
program names from the log output are.
rip Routing Information Protocol (RIP)
ripng Routing Information Protocol - next generation (RIPng)
ospf Open Shortest Path First (OSPF)
ospfv3 Open Shortest Path First (OSPF) version 3 (OSPFv3)
bgp Border Gateway Protocol (BGP)

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals