C613-50631-01 Rev A Command Reference for IE340 Series 2305
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
AUTHENTICATION COMMANDS
AUTH
-WEB-SERVER PING-POLL REAUTH-TIMER-REFRESH
auth-web-server ping-poll
reauth-timer-refresh
Overview This command modifies the reauth-timer-refresh parameter for the
Web-Authentication feature. The reauth-timer-refresh parameter specifies
whether a re-authentication timer is reset and when the response from a
supplicant (a client device) is received.
Use the no variant of this command to reset the reauth-timer-refresh parameter
to the default setting (disabled).
Syntax
auth-web-server ping-poll reauth-timer-refresh
no auth-web-server ping-poll reauth-timer-refresh
Default The reauth-timer-refresh parameter is disabled by default.
Mode Global Configuration
Examples To enable the reauth-timer-refresh timer, use the following commands:
awplus# configure terminal
awplus(config)# auth-web-server ping-poll reauth-timer-refresh
To disable the reauth-timer-refresh timer, use the following commands:
awplus# configure terminal
awplus(config)# no auth-web-server ping-poll
reauth-timer-refresh
Validation
Commands
show auth
show auth-web-server
show running-config

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals