EasyManuals Logo

Allied Telesis IE340 Series User Manual

Allied Telesis IE340 Series
3474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3292 background imageLoading...
Page #3292 background image
C613-50631-01 Rev A Command Reference for IE340 Series 3292
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
RMON COMMANDS
RMON
COLLECTION HISTORY
rmon collection history
Overview Use this command to create a history statistics control group to store a specified
number of snapshots (buckets) of the standard RMON statistics for the switch port,
and to collect these statistics at specified intervals. If there is sufficient memory
available, then the device will allocate memory for storing the set of buckets that
comprise this history control.
Use the no variant of this command to remove the specified history control
configuration.
NOTE: A history can only be collected for switch port interfaces, not for VLANs.
Syntax
rmon collection history <history-index> [buckets <1-65535>]
[interval <1-3600>] [owner <owner>]
no rmon collection history <history-index>
Default The default interval is 1800 seconds and the default number of buckets is 50.
Mode Interface Configuration
Example To create a history statistics control group with ID 200 to store 500 snapshots with
an interval of 600 seconds, use the commands:
awplus# configure terminal
awplus(config)# interface port1.0.2
awplus(config-if)# rmon collection history 200 buckets 500
interval 600 owner herbert
To disable the history statistics control group, use the commands:
awplus# configure terminal
awplus(config)# interface port1.0.2
awplus(config-if)# no rmon collection history 200
Related
commands
rmon alarm
rmon collection stats
rmon event
Parameter Description
<history-index> A unique RMON history control entry index value from the
range 1 to 65535.
buckets <1-65535> Number of requested buckets to store snapshots from the
range 1 to 65535. The default is 50 buckets.
interval <1-3600> Polling interval in seconds. Default 1800 second polling
interval from the range 1 to 3600.
owner <owner> Owner name to identify the entry.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals