Page #582 background image
C613-50631-01 Rev A Command Reference for IE340 Series 582
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
SWITCHING COMMANDS
LOOP
-PROTECTION TIMEOUT
loop-protection timeout
Overview Use this command to specify the Loop Protection recovery action duration on an
interface.
Use the no variant of this command to set the loop protection timeout to the
default.
Syntax
loop-protection timeout <duration>
no loop-protection timeout
Default The default is 7 seconds.
Mode Interface Configuration
Usage notes See the “Loop Protection” section in the Switching_Feature Overview_and
Configuration_Guide for relevant conceptual, configuration, and overview
information prior to applying this command.
Example To configure a loop protection action timeout of 10 seconds for port1.0.4, use the
command:
awplus# configure terminal
awplus(config)# interface port1.0.4
awplus(config-if)# loop-protection timeout 10
Related
commands
loop-protection loop-detect
loop-protection action
show loop-protection
Parameter Description
<duration> The time (in seconds) for which the configured action will apply
before being disabled. This duration can be set between 0 and 86400
seconds (24 hours). The set of 0 means infinity so timeout does not
expire.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals