SWITCHING COMMANDS
LOOP
-PROTECTION TIMEOUT
loop-protection timeout
Overview Use this command to specify the Loop Protection recovery action duration on an
interface.
Use the no variant of this command to set the loop protection timeout to the
default.
Syntax
loop-protection timeout <duration>
no loop-protection timeout
Default The default is 7 seconds.
Mode Interface Configuration
Usage notes See the “Loop Protection” section in the Switching_Feature Overview_and
Configuration_Guide for relevant conceptual, configuration, and overview
information prior to applying this command.
Example To configure a loop protection action timeout of 10 seconds for port1.0.4, use the
command:
awplus# configure terminal
awplus(config)# interface port1.0.4
awplus(config-if)# loop-protection timeout 10
Related
commands
loop-protection loop-detect
loop-protection action
show loop-protection
Parameter Description
<duration> The time (in seconds) for which the configured action will apply
before being disabled. This duration can be set between 0 and 86400
seconds (24 hours). The set of 0 means infinity so timeout does not
expire.