C613-50631-01 Rev A Command Reference for IE340 Series 532
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY G8032 LED
alarm facility g8032 led
Overview Use this command to make the fault LED flash if one or more G.8032 ERP instances
are in the PROTECTION state.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility g8032 led
no alarm facility g8032 led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility g8032 relay.
Example To flash the LED if one or more G.8032 ERP instances are in the PROTECTION state,
use the commands:
awplus# configure terminal
awplus(config)# alarm facility g8032 led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility g8032 led
Related
commands
alarm facility g8032 relay
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals