C613-50631-01 Rev A Command Reference for IE340 Series 339
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
PLUGGABLES AND CABLING COMMANDS
FIBER
-MONITORING INTERVAL
fiber-monitoring interval
Overview Use this command to configure the fiber monitoring polling interval in seconds for
the port. The optical power will be read every <interval> seconds and compared
against the calculated threshold values to see if a log message or other action is
required.
Use the no variant of this command to reset the polling interval to the default (5
seconds).
Syntax
fiber-monitoring interval <2-60>
no fiber-monitoring interval
Default The interval is set to 5 seconds by default.
Mode Interface configuration mode for a fiber port.
Example To set the fiber monitoring polling interval for port1.0.1 to 30 seconds, use the
commands:
awplus(config)# interface port1.0.1
awplus(config-if)# fiber-monitoring interval 30
To reset the fiber monitoring polling interval back to the default (5s), use the
commands:
awplus(config)# interface port1.0.1
awplus(config-if)# no fiber-monitoring interval
Related
commands
fiber-monitoring baseline
show system fiber-monitoring
Parameter Description
<2-60> Optical power polling interval in seconds.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals