C613-50631-01 Rev A Command Reference for IE340 Series 467
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LOGGING COMMANDS
LOG
HOST TIME
log host time
Overview This command configures the time used in messages sent to a remote syslog
server. If the syslog server is in a different time zone to your device then the time
offset can be configured using either the utc-offset parameter option keyword or
the local-offset parameter option keyword, where utc-offset is the time
difference from UTC (Universal Time, Coordinated) and local-offset is the
difference from local time.
Syntax
log host {<hostname>|<ipv4-addr>|<ipv6-addr>} time
{local|local-offset|utc-offset {plus|minus} <0-24>}
Default The default is local time.
Mode Global Configuration
Usage notes Use the local option if the remote syslog server is in the same time zone as the
device. Messages will display the time as on the local device when the message
was generated.
Use the offset option if the email recipient is in a different time zone to this device.
Specify the time offset of the remote syslog server in hours. Messages will display
the time they were generated on this device but converted to the time zone of the
remote syslog server.
Parameter Description
<hostname> The host name of a remote syslog server.
<ipv4-addr> The IPv4 address of a remote syslog server, in A.B.C.D format.
<ipv6-addr> The IPv6 address of a remote syslog server, in X:X::X:X format.
<email-address> The email address to send log messages to
time Specify the time difference between the email recipient and the
device you are configuring.
local The device is in the same time zone as the email recipient
local-offset The device is in a different time zone to the email recipient. Use
the plus or minus keywords and specify the difference (offset)
from local time of the device to the email recipient in hours.
utc-offset The device is in a different time zone to the email recipient. Use
the plus or minus keywords and specify the difference (offset)
from UTC time of the device to the email recipient in hours.
plus Negative offset (difference) from the device to the syslog server.
minus Positive offset (difference) from the device to the syslog server.
<0-24> World Time zone offset in hours

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals