C613-50631-01 Rev A Command Reference for IE340 Series 395
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
CONNECTIVITY FAULT MANAGEMENT COMMANDS
SHOW
ETHERNET CFM MAINTENANCE-POINTS REMOTE MEP
show ethernet cfm maintenance-points
remote mep
Overview Use this command to show one or more Ethernet CFM maintenance points,
namely Remote Maintenance End Points (MEPs) within a given Maintenance
Association (MA) and its associated Maintenance Domain (MD), and their
configuration and status in summary format. Options include the ability to show
an individual Remote MEP in detail.
Syntax
show ethernet cfm maintenance-points remote mep domain
<domain-name> service <ma-name> [{mac <rmep-mac-address>|rmep
<mep-id>} details]
Mode User Exec/Privileged Exec
Example To show all the remote MEP(s)'s status for this MA and MD in summary form, use
the command:
awplus# show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1
To show a specific remote MEP by its ID in detail, use the command:
awplus# show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1 rmep 21 details
To show a specific remote MEP by its MAC address in detail, use the command:
awplus# show ethernet cfm maintenance-points remote mep domain
MD-INST1 service MA-INST1-1 mac 000c.2526.95bf details
Parameter Description
domain Specify the Maintenance Domain that Remote MEP(s) are to
be shown for.
<domain-name> Specify the Maintenance Domain's CLI instance name.
service Specify the Maintenance Association that the Remote
MEP(s) are to be shown for.
<ma-name> Specify the service's (Maintenance Association (MA)) CLI
instance name.
mac Specify the remote MEP of interest by its MAC address.
<rmep-mac-address> Specify the value of the remote MEP's MAC address using
the format HHHH.HHHH.HHHH where H is a hexadecimal
digit.
rmep Specify the remote MEP of interest by its ID.
<mep-id> Specify the value of the remote MEP's ID in the range 1 to
8191.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals