C613-50631-01 Rev A Command Reference for IE340 Series 417
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LOGGING COMMANDS
DEFAULT
LOG PERMANENT
default log permanent
Overview This command restores the default settings for the permanent log stored in NVS.
By default, the size of the permanent log is 50 kB and it accepts messages with the
severity level of warnings and above.
Syntax
default log permanent
Default The permanent log is enabled by default.
Mode Global Configuration
Example To restore the permanent log to its default settings use the following commands:
awplus# configure terminal
awplus(config)# default log permanent
Related
commands
clear log permanent
log permanent
log permanent (filter)
log permanent exclude
log permanent size
show log config