C613-50631-01 Rev A Command Reference for IE340 Series 3199
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
SNMP COMMANDS
SNMP
-SERVER ENGINEID LOCAL RESET
snmp-server engineID local reset
Overview Use this command to force the device to generate a new pseudo-random SNMPv3
engine ID by resetting the SNMPv3 engine. If the current engine ID is user defined,
use the snmp-server engineID local command to set SNMPv3 engine ID to a system
generated value.
Syntax
snmp-server engineID local reset
Mode Global Configuration
Example To force the SNMPv3 engine ID to be reset to a system generated value, use the
commands:
awplus# configure terminal
awplus(config)# snmp-server engineID local reset
Related
commands
snmp-server engineID local
show snmp-server