C613-50631-01 Rev A Command Reference for IE340 Series 387
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
CONNECTIVITY FAULT MANAGEMENT COMMANDS
SHOW
ETHERNET CFM ERRORLOG
show ethernet cfm errorlog
Overview Use this command to list the CFM Errors that are in the CFM Errors Event List,
starting from the oldest at the top to the latest at the end.
Syntax
show ethernet cfm errorlog domain <domain-name>
Mode Privileged Exec
Usage notes When a new error is detected for a Maintenance Association (MA) that is associated
with a Maintenance Domain (MD), and such is due to an error from a received or
missing CCM from a Remote MEP, an event is logged to the CFM Errors Event List.
Example To show the list of errors for an MD named “MD-INST2”, use the command:
awplus# show ethernet cfm errorlog domain MD-INST2
Output Figure 9-5: Example output from show ethernet cfm errorlog domain
MD-INST2
Parameter Description
<domain-name> Specify the domain name value.
awplus#show ethernet cfm errorlog domain MD-INST2ď€
ď€
CFM Service Name Level VLAN MEPID Remote MAC Error Reasonď€
------------------------------------------------------------------ď€
MA-INST2-1 0 0 12 0000.0000.0000 Remote MEP Down
Table 9-3: Parameters in the output from show ethernet cfm errorlog domain
MD-INST2
Parameter Description
Level The level configured for the MD.
VLAN The VLAN ID used by the MA if any, otherwise is "0".
MEPID The MEP ID of the local MEP that detected the error.
Remote MAC The source MAC address of the received CCM causing the
error if known, 0000.0000.0000 otherwise.