C613-50631-01 Rev A Command Reference for IE340 Series 482
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
LOGGING COMMANDS
LOG
PERMANENT SIZE
log permanent size
Overview This command configures the amount of memory that the permanent log is
permitted to use. Once this memory allocation has been filled old messages will be
deleted to make room for new messages.
Use the no variant of this command to return to the default.
Syntax
log permanent size <50-250>
no log permanent size
Default 50 kilobytes
Mode Global Configuration
Example To allow the permanent log to use up to 100 kilobytes of NVS, use the commands:
awplus# configure terminal
awplus(config)# log permanent size 100
To return to the default value, use the commands:
awplus# configure terminal
awplus(config)# no log permanent size
Related
commands
clear log permanent
copy permanent-log
default log permanent
log permanent
log permanent (filter)
log permanent exclude
show log config
show log permanent
Parameter Description
<50-250> Size of the permanent log in kilobytes

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals