C613-50631-01 Rev A Command Reference for IE340 Series 543
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY MAIN-PSE LED
alarm facility main-pse led
Overview Use this command to make the fault LED flash if the total power consumed by all
of the PoE devices plugged into the switch exceeds the maximum PoE output
permitted.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility main-pse led
no alarm facility main-pse led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility main-pse relay.
Example To flash the LED if the total power consumed by all of the PoE devices plugged into
the switch exceeds the maximum PoE output permitted, use the commands:
awplus# configure terminal
awplus(config)# alarm facility main-pse led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility main-pse led
Related
commands
alarm facility main-pse relay
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: input-member and output-member parameters added on
IE510-28GSX switches

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals