C613-50631-01 Rev A Command Reference for IE340 Series 3469
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
MODBUS COMMANDS
SCADA
MODBUS TCP SERVER PORT
scada modbus tcp server port
Overview Use this command to set the port of the MODBUS TCP server on a device. Clients
will use this port to connect to the MODBUS TCP server.
Use the no variant of this command to disable MODBUS TCP.
Syntax
scada modbus tcp server port <0-65535>
no scada modbus tcp server
Default Port 502
Mode Global Configuration
Example To configure port number 34567 as the MODBUS TCP server, use the following
commands:
awplus# configure terminal
awplus(config)# scada modbus tcp server port 34567
To reset the port number of the MODBUS TCP server to the default of 502, use the
following commands:
awplus# configure terminal
awplus(config)# no scada modbus tcp server port
Related
commands
show scada modbus tcp server
scada modbus tcp server connection
scada modbus tcp server access
clear scada modbus tcp server connection
clear scada modbus tcp server statistics
show scada modbus tcp server connections
Command
changes
Version 5.4.8-2.1: command added
Version 5.4.9-0.1: MODBUS support added for x930, x950 series
Version 5.5.0-1.1: MODBUS support added for IE510 series
Parameter Description
<0-65535> The port number of the MODBUS TCP server

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals