ALARM MONITORING COMMANDS
ALARM
FACILITY LOOPPROT LED
alarm facility loopprot led
Overview Use this command to make the fault LED flash if the loop protection feature detects
a loop.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility loopprot led
no alarm facility loopprot led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility loopprot relay.
Example To flash the LED if loop protection detects a loop, use the commands:
awplus# configure terminal
awplus(config)# alarm facility loopprot led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility loopprot led
Related
commands
alarm facility loopprot relay
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: output-member parameter added on IE510-28GSX switches