C613-50631-01 Rev A Command Reference for IE340 Series 2743
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
G.8032 ETHERNET RING PROTECTION SWITCHING COMMANDS
TRAP
(G8032-SWITCH)
trap (g8032-switch)
Overview Use this command to enable or disable SNMP traps for a G.8032 Ethernet Ring
Protection (ERP) instance.
Syntax
trap {enabled|disabled}
Default The SNMP traps for the ERP instance are enabled.
Mode G8032 Configure Switch
Usage notes Globally, ERP traps are disabled by default but can be enabled globally using the
snmp-server enable trap command.
Example To disable the SNMP traps for an ERP instance named “blue”, use the following
commands:
awplus(config)# g8032 erp-instance blue
awplus(g8032-config-switch)# trap disabled
Related
commands
erp-instance
show g8032 erp-instance
snmp-server enable trap
Command
changes
Version 5.4.7-0.1: command added
Version 5.4.7-1.1: added to x310 series products
Version 5.4.7-2.1: added to x550 series products
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products
Parameter Description
enabled Enable this ERP instance to generate traps.
disabled Disable this ERP instance from generating traps.