C613-50631-01 Rev A Command Reference for IE340 Series 2742
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
G.8032 ETHERNET RING PROTECTION SWITCHING COMMANDS
TOPOLOGY
-CHANGE
Example To enable sending of R-APS flush event messages on an ERP instance named
“blue”, use the following commands:
awplus(config)# g8032 erp-instance blue
awplus(g8032-config-switch)# topology-change g8032
Related
commands
g8032 erp-instance
show g8032 erp-instance
Command
changes
Version 5.4.7-0.1: command added
Version 5.4.7-1.1: added to x310 series products
Version 5.4.7-2.1: added to x550 series products
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products

Table of Contents