C613-50631-01 Rev A Command Reference for IE340 Series 545
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY POWER-SUPPLY LED
alarm facility power-supply led
Overview Use this command to make the fault LED flash if a specified power supply is not
supplying power.
Note that if both of the switch’s power supplies stop supplying power, the switch’s
LED will not flash, because the switch will turn off. To trigger alarms if both power
supplies go down, use the alarm relay instead (alarm facility power-supply relay).
Use the no variant of this command to remove this alarm.
Syntax
alarm facility power-supply <power-supply-number> led
no alarm facility power-supply led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility power-supply relay.
Example To flash the LED if power supply 2 goes down, use the commands:
awplus# configure terminal
awplus(config)# alarm facility power-supply 2 led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility power-supply 2 led
Related
commands
alarm facility power-supply relay
show alarm facility settings
show alarm facility status
Command
changes
Version 5.4.9-1.1: input-member and output-member parameters added on
IE510-28GSX switches
Parameter Description
power-supply
<power-supply-number>
The number of the power supply you want to monitor
with this alarm. The switch has two power supplies, so
the number is 1 or 2.