C613-50631-01 Rev A Command Reference for IE340 Series 1879
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
PIM-SMV6 COMMANDS
IPV
6 PIM RP-REGISTER-KAT
ipv6 pim rp-register-kat
Overview Use this command to configure the Keep Alive Time (KAT) for (S,G) states at the RP
(Rendezvous Point) to monitor PIM-SMv6 Register packets.
Use the no variant of this command to return the PIM-SMv6 KAT timer to its default
value of 210 seconds.
Syntax
ipv6 pim rp-register-kat <1-65535>
no ipv6 pim rp-register-kat
Mode Global Configuration
Default The default PIM-SMv6 KAT timer value is 210 seconds.
Examples
awplus# configure terminal
awplus(config)# ipv6 forwarding
awplus(config)# ipv6 multicast-routing
awplus(config)# ipv6 pim rp-register-kat 3454
awplus# configure terminal
awplus(config)# no ipv6 pim rp-register-kat
Related
commands
ipv6 pim rp-address
ipv6 pim rp-candidate
Parameter Description
<1-65536> Specify the KAT timer in seconds. The default value is 210 seconds.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals