C613-50631-01 Rev A Command Reference for IE340 Series 551
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY TEMPERATURE RELAY
alarm facility temperature relay
Overview Use this command to make the fault LED flash if the switch’s temperature exceeds
the high limit for any of its monitored temperature thresholds.
This will activate the device that you have connected to the switch’s relay output
(for example, you could connect a buzzer to the relay output).
To see the limits, use the command show system environment.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility temperature relay
no alarm facility temperature relay
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use an alarm to flash the fault LED, by using the command alarm
facility temperature led.
Example To trigger the alarm relay if the switch overheats, use the commands:
awplus# configure terminal
awplus(config)# alarm facility temperature relay
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility temperature relay
Related
commands
alarm facility temperature led
show alarm facility settings
show alarm facility status
show system environment
Command
changes
Version 5.4.9-1.1: input-member and output-member parameters added on
IE510-28GSX switches