EasyManuals Logo

Allied Telesis IE340 Series User Manual

Allied Telesis IE340 Series
3474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1599 background imageLoading...
Page #1599 background image
C613-50631-01 Rev A Command Reference for IE340 Series 1599
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
BGP AND BGP4+ COMMANDS
TIMERS
(BGP)
timers (BGP)
Overview Use this command sets the BGP keepalive timer and holdtime timer values.
Use the no variant of this command to reset timers to the default.
Syntax
timers bgp <keepalive> <holdtime>
no timers bgp [<keepalive> <holdtime>]
Default The keepalive timer default is 60 seconds, the holdtime timer default is 90 seconds,
and the connect timer default is 120 seconds as per RFC 4271. Holdtime is
keepalive * 3.
Mode Router Configuration
Usage notes This command is used globally to set or unset the keepalive and holdtime values
for all the neighbors.
Examples
awplus# configure terminal
awplus(config)# router bgp 10
awplus(config-router)# timers bgp 40 120
awplus# configure terminal
awplus(config)# router bgp 10
awplus(config-router)# no timers bgp 30 90
awplus# configure terminal
awplus(config)# router bgp 10
awplus(config-router)# no timers bgp
Related
commands
neighbor timers
show ip bgp neighbors hold-time (BGP only)
show ip bgp neighbors keepalive-interval (BGP only)
Parameter Description
<keepalive> <0-65535> The frequency with which the keepalive messages are
sent to the neighbors. The default is 30 seconds as per RFC 4271.
Cisco IOS uses a 60 second keepalive timer default value. Adjust
keepalive timers for interoperability as required. Maintain the
keepalive value at the holdtime value / 3.
<holdtime> <0-65535> The interval after which the neighbor is considered
dead if keepalive messages are not received. The default
holdtime value is 90 seconds as per RFC 4271.
Cisco IOS uses a 180 second holdtime timer default value. Adjust
holdtime timers for interoperability as required. Maintain the
holdtime value at the keepalive value * 3.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals