C613-50631-01 Rev A Command Reference for IE340 Series 550
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
ALARM MONITORING COMMANDS
ALARM
FACILITY TEMPERATURE LED
alarm facility temperature led
Overview Use this command to make the fault LED flash if the switch’s temperature goes
above the high limit for any of its monitored temperature thresholds. To see the
limits, use the command show system environment.
Use the no variant of this command to remove this alarm.
Syntax
alarm facility temperature led
no alarm facility temperature led
Default By default, there are no alarms
Mode Global Configuration
Usage notes You can also use a relay to trigger an external alarm output, such as a buzzer, by
using the command alarm facility temperature relay.
Example To flash the LED if the switch overheats, use the commands:
awplus# configure terminal
awplus(config)# alarm facility temperature led
To remove that alarm, use the commands:
awplus# configure terminal
awplus(config)# no alarm facility temperature led
Related
commands
alarm facility temperature relay
show alarm facility settings
show alarm facility status
show system environment
Command
changes
Version 5.4.9-1.1: input-member and output-member parameters added on
IE510-28GSX switches