C613-50631-01 Rev A Command Reference for IE340 Series 1945
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
IPV4 HARDWARE ACCESS CONTROL LIST (ACL) COMMANDS
ACCESS
-LIST (NUMBERED HARDWARE ACL FOR ICMP)
Parameter Description
<3000-3699> An ID number for this hardware IP access-list.
<action> The action that the switch will take on matching packets. See the
table above for valid values.
icmp Match against ICMP packets
<source-ip> The source addresses to match against. You can specify a single
host, a subnet, or all source addresses. The following are the valid
formats for specifying the source:
any Match any source IP address.
host <ip-addr> Match a single source host with the
IP address given by <ip-addr> in
dotted decimal notation.
<ip-addr>/<prefix> Match any source IP address within
the specified subnet. Specify the
subnet by entering the IPv4 address,
then a forward slash, then the prefix
length.
<ip-addr>
<reverse-mask>
Match any source IP address within
the specified subnet. Specify the
subnet by entering a reverse mask in
dotted decimal format. For example,
entering “192.168.1.1 0.0.0.255” is the
same as entering 192.168.1.1/24.
<dest-ip> The destination addresses to match against. You can specify a
single host, a subnet, or all destination addresses. The following
are the valid formats for specifying the destination:
any Match any destination IP address.
host <ip-addr> Match a single destination host with
the IP address given by <ip-addr> in
dotted decimal notation.
<ip-addr>/<prefix> Match any destination IP address
within the specified subnet. Specify
the subnet by entering the IPv4
address, then a forward slash, then
the prefix length.
<ip-addr>
<reverse-mask>
Match any destination IP address
within the specified subnet. Specify
the subnet by entering a reverse
mask in dotted decimal format. For
example, entering “192.168.1.1
0.0.0.255” is the same as entering
192.168.1.1/24.
icmp-type
<number>
The type of ICMP message to match against, as defined in RFC792
and RFC950. Values include:
0 Echo replies.

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals