C613-50631-01 Rev A Command Reference for IE340 Series 271
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
SYSTEM CONFIGURATION AND MONITORING COMMANDS
CONTINUOUS
-REBOOT-PREVENTION
Examples To enable continuous reboot prevention, use the commands:
awplus# configure terminal
awplus(config)# continuous-reboot-prevention enable
To set the period to 500 and action to stopreboot, use the commands:
awplus# configure terminal
awplus(config)# continuous-reboot-prevention period 500 action
stopreboot
To return the period and action to the defaults and keep the continuous reboot
prevention feature enabled, use the commands:
awplus# configure terminal
awplus(config)# no continuous-reboot-prevention period action
To disable continuous reboot prevention, use the commands:
awplus# configure terminal
awplus(config)# no continuous-reboot-prevention enable