C613-50631-01 Rev A Command Reference for IE340 Series 3158
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
PRECISION TIME PROTOCOL (PTP) AND TRANSPARENT CLOCK COMMANDS
PTP
-CLK
Usage notes The clock is not active until the PTP timing service is enabled via the ptp global
command. It is not possible to make a port a clock port - if the clock has not been
configured.
Example To configure a PTP instance on the switch, use the following commands:
awplus# configure terminal
awplus(config)# ptp-clk transparent transport-type ethernet
delay-mechanism e2e step-type onestep
Related
commands
ptp global
show ptp data transparent
show ptp port
Command
changes
Version 5.4.7- 0.1: command added