C613-50631-01 Rev A Command Reference for IE340 Series 335
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
PLUGGABLES AND CABLING COMMANDS
FIBER
-MONITORING ACTION
To set the device to stop shutting down the port if port1.0.1 or port1.0.4 receive
reduced power, use the commands:
awplus(config)# interface port1.0.1-port1.0.4
awplus(config-if)# no fiber-monitoring action shutdown
If the device is set to send an SNMP trap for those ports, it will continue to do so.
To set the device not to perform any action when it receives reduced power on
port1.0.1 or port1.0.4, except sending a log message, use the commands:
awplus(config)# interface port1.0.1-port1.0.4
awplus(config-if)# no fiber-monitoring action
Related
commands
fiber-monitoring sensitivity
show system fiber-monitoring
Command
changes
Version 5.4.8-0.2: continuous parameter added