C613-50631-01 Rev A Command Reference for IE340 Series 375
AlliedWare Plus™ Operating System - Version 5.5.3-0.x
CONNECTIVITY FAULT MANAGEMENT COMMANDS
MEP
CROSSCHECK
in an MD/MA that is not subject to topology loops. A Down MP can be VLAN
aware or link-local.
An MEP can be either Up or Down for a given MD/MA, but within a bridge for the
same MD/MA, there can only be one Up or Down MEP (not both). An Up MEP must
be VLAN aware. A Down MEP may be VLAN aware. Otherwise, a Down MEP is
allowed to be link local (VLAN unaware), and its scope is that of the entire link.
Example To create a remote MEP instance named “MA-INST2-1” with an MEP ID of 21, use
the command:
awplus(config-ether-cfm)# mep crosscheck mpid 21 ma-name
MA-INST2-1
To destroy the remote MEP instance named “MA-INST2-1” with the MEP ID of 21,
use the command:
awplus(config-ether-cfm)# no mep crosscheck mpid 21 ma-name
MA-INST2-1
Related
commands
cc unicast
ethernet cfm domain-name
ethernet cfm mep
service ma-name
show ethernet cfm errorlog
show ethernet cfm maintenance-points remote mep
show ethernet cfm service
show mep-alarm status
Command
changes
Version 5.4.7-1.1: command added
Version 5.4.8-0.2: added to SBx8100 series products
Version 5.4.8-1.1: added to SBx908 GEN2 series products

Table of Contents

Other manuals for Allied Telesis IE340 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis IE340 Series and is the answer not in the manual?

Allied Telesis IE340 Series Specifications

General IconGeneral
BrandAllied Telesis
ModelIE340 Series
CategorySwitch
LanguageEnglish

Related product manuals