Parameters
List of parameters
1-100
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
When copying, p0131 is not taken into account.
Description: Sets the number of Encoder Data Sets (EDS).
Note: When parameterizing the drive with "no encoder" there must be at least one encoder data set (p0140 >= 1).
Description: This parameter is used to assign the encoder data set to an encoder evaluation (e.g. SMC).
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to an encoder evaluation.
Note: If the encoder evaluation and encoder are integrated (motor with DRIVE-CLiQ), then their component numbers are
identical.
For an SMC, different component numbers are assigned for the SMC (p0141) and the (actual) encoder (p0142).
Description: This parameter is used to assign the encoder data set to an encoder.
This assignment is made using the unique component number that was assigned when parameterizing the topol-
ogy.
Only component numbers can be entered into this parameter that correspond to an encoder.
Note: If the encoder evaluation and encoder are integrated (motor with DRIVE-CLiQ), then their component numbers are
identical.
For an SMC, different component numbers are assigned for the SMC (p0141) and the (actual) encoder (p0142).
Description: Detects the Voltage Sensing Module (VSM) module assigned to this infeed.
p0140 Number of Encoder Data Sets (EDS) / EDS count
SERVO, VECTOR Can be changed: C1(3) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 16 1
p0141[0...n] Encoder interface (Sensor Module) component number / Enc_interf comp_no
SERVO, VECTOR Can be changed: C1(4) Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: EDS, p0140 Func. diagram: 4704, 8570
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0142[0...n] Encoder component number / Encoder comp_no
SERVO, VECTOR Can be changed: C1(4) Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: EDS, p0140 Func. diagram: 4704
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0144[0...n] Voltage sensing module detection via LED / VSM detection LED
A_INF, S_INF Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0