Parameters
List of parameters
1-930
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the ACX file saved in the appropriate directory of the CompactFlash card.
Dependency: Refer to: p1500
Note: For a value = 9999999, the following applies: The read operation is still running.
Description: Indicates which macro is presently being run in the drive object.
Dependency: Refer to: p0015, p0700, p1000, p1500, r8570, r8571, r8572, r8573
Description: Displays all of the devices connected to the CAN bus after run-up.
r8600
= 00000000 hex: No drive recognized.
= FFFF0192 hex: Several drives - drive 1 is an Active Line Module, servo drive or vector drive
= FFFF0191 hex: Several drives - 1st drive us a Terminal Module
= 00010192 hex: 1 Vector drive
= 00020192 hex: 1 Servo drive
= 01000192 hex: 1 Active Line Module
= 00080191 hex: 1 Terminal Module
Note: Corresponds to the CANopen object 1000 hex.
For each detected drive, the device type is displayed in object 67FF hex + 800 hex * x (x: Drive number 0 ... 7).
Description: Displays the error register for CANopen.
Bit 0: Generic error
0 signal: No error present
r8573[0...29] Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r8585 Actual macro actual / Actual macro
A_INF, B_INF,
CU_CX32, CU_S,
SERVO, S_INF,
TM15DI_DO, TM31,
VECTOR
Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 0
Min Max Factory setting
- - -
r8600 CBC device type / Device type
CU_S (CAN) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r8601 CBC error register / Error register
CU_S (CAN) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -