Siemens SINAMICS S Series - p2037 PROFIdrive STW1.10 = 0 mode; PD STW1.10=0 mode; p2038 PROFIdrive STW;ZSW interface mode; PD STW;ZSW IF mode

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-531
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the processing mode for PROFIdrive STW1.10 "master control by PLC".
Generally, control world 1 is received with the first receive word (PZD1) (this is in conformance to the PROFIdrive
profile). The behavior of STW1.10 = 0 corresponds to that of the PROFIdrive profile. For other applications that
deviate from this, the behavior can be adapted using this particular parameter.
Values: 0: Freeze setpoints and continue to process sign-of-life
1: Freeze setpoints and sign-of-life
2: Setpoints are not frozen
Recommend.: Do not change the setting p2037 = 0.
Note: If the STW1 is not transferred according to the PROFIdrive with PZD1 (with bit 10 "master control by PLC"), then
p2037 should be set to 2.
Description: Sets the interface mode of the PROFIdrive control and status words.
When selecting a telegram via p0922 (p2079), this parameter influences the device-specific assignment of the bits
in the control and status words.
Values: 0: SINAMICS
1: SIMODRIVE 611 universal
2: VIK-NAMUR
Dependency: Refer to: p0922, p2079
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For p0922 (p2079) = 100 ... 199, p2038 is automatically set to 1 and p2038 can no longer be changed. This means
that for these telegrams, the "SIMODRIVE 611 universal" interface mode is set and cannot be changed.
Description: Displays the interface mode of the PROFIdrive control and status words.
Values: 0: SINAMICS
Dependency: Refer to: p0922, p2079
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: For p0922 (p2079) = 7, 9 , 110, p2038 is automatically set to 0 and cannot be changed.
p2037 PROFIdrive STW1.10 = 0 mode / PD STW1.10=0 mode
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 0
p2038 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
SERVO, VECTOR Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 2 0
p2038 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
SERVO (EPOS),
SERVO (Pos ctrl),
VECTOR (EPOS),
VECTOR (Pos ctrl)
Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 0 0