Parameters
List of parameters
1-54
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p0290, p0294
Refer to: F30005
Description: Displays the Control Unit temperature.
An appropriate signal is output when 85°C is exceeded.
Index: [0] = Control Unit temperature actual
[1] = Control Unit temperature maximum
Dependency: Refer to: A01009
Note: The value of -200 indicates that there is no measuring signal.
Re r0037[0]:
Displays the currently measured Control Unit temperature.
Re r0037[1]:
Displays the highest measured Control Unit temperature. This value is saved on the module in a non-volatile fash-
ion.
Description: Displays the temperatures in the power unit.
Index: [0] = Maximum inverter
[1] = Maximum depletion layer
[2] = Maximum rectifier
[3] = Air intake
[4] = Electronics unit in the power unit
[5] = Inverter 1
[6] = Inverter 2
[7] = Inverter 3
[8] = Inverter 4
[9] = Inverter 5
[10] = Inverter 6
[11] = Rectifier 1
[12] = Rectifier 2
[13] = Depletion layer 1
[14] = Depletion layer 2
[15] = Depletion layer 3
[16] = Depletion layer 4
[17] = Depletion layer 5
[18] = Depletion layer 6
[19] = Cooling system, liquid intake
Note: The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
r0037[0...1] Control Unit temperature / CU temperature
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Displays, signals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]
r0037[0...19] CO: Power unit temperatures / PU temperatures
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 8014
P-Group: Displays, signals Units group: 21_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [°C] - [°C] - [°C]