List of parameters
Parameters
1-65
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: r0020
Note: The velocity setpoint is available smoothed (r0020) and unsmoothed (r0060).
Description: Displays the speed sensed by the motor encoder (unsmoothed).
Description: Displays the velocity sensed by the motor encoder (unsmoothed).
Description: Displays the speed sensed by the motor encoder (unsmoothed).
Index: [0] = Encoder 1
[1] = Encoder 2
Description: Displays the actual speed setpoint after the setpoint filters.
r0061 CO: Speed actual value motor encoder / n_ist mot. encoder
SERVO Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1580, 4710,
4715
P-Group: Displays, signals Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r0061 CO: Velocity actual value, motor encoder / v_act mot encoder
SERVO (Lin) Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1580, 4710,
4715
P-Group: Displays, signals Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
r0061[0...1] CO: Speed actual value motor encoder / n_ist mot. encoder
VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: 1580, 4710,
4715
P-Group: Displays, signals Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r0062 CO: Speed setpoint after the filter / n_set after filter
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1590, 1750,
5020, 5030, 5210, 6030
P-Group: Displays, signals Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]