List of parameters
Parameters
1-539
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: IF1: Interface 1
Description: Displays the PZD (actual values) with word format sent to the PROFIBUS master.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Note: IF1: Interface 1
Description: Displays the PZD (actual values) with word format sent to the PROFIBUS master.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
10 Bit 10 On Off -
11 Bit 11 On Off -
12 Bit 12 On Off -
13 Bit 13 On Off -
14 Bit 14 On Off -
15 Bit 15 On Off -
r2053[0...7] IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
A_INF, B_INF,
S_INF
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 On Off -
01 Bit 1 On Off -
02 Bit 2 On Off -
03 Bit 3 On Off -
04 Bit 4 On Off -
05 Bit 5 On Off -
06 Bit 6 On Off -
07 Bit 7 On Off -
08 Bit 8 On Off -
09 Bit 9 On Off -
10 Bit 10 On Off -
11 Bit 11 On Off -
12 Bit 12 On Off -
13 Bit 13 On Off -
14 Bit 14 On Off -
15 Bit 15 On Off -
r2053[0...18] IF1 PROFIdrive diagnostics PZD send word / IF1 diag send word
SERVO, TM41 Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2450, 2470
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -