Parameters
List of parameters
1-84
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: The application-specific view of an existing drive object is entered into each index.
The parameter cannot be changed.
Dependency: Refer to: p0107, r0107
Refer to: F01051
Note: The application-specific views are defined in files on the CompactFlash card with the following structure:
PDxxxyyy.ACX
xxx: Application-specific view (p0103)
yyy: Type of drive object (p0107)
Example:
PD052011.ACX
--> "011" stands for the drive object, type SERVO
--> "052" is the number of the view for this drive object
Description: Displays the application-specific view of the individual drive object.
Dependency: Refer to: p0107, r0107
Refer to: F01051
Description: Setting to activate/de-activate a drive object.
Values: 0: De-activate drive object
1: Activate drive object
Dependency: Refer to: r0106
Notice: The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be canceled.
p0103[0...15] Application-specific view / Appl_spec view
CU_CX32, CU_S Can be changed: C1(2) Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 999 0
r0103 Application-specific view / Appl_spec view
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 65535 -
p0105 Activate/de-activate drive object / DO act/de-act
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S Series and is the answer not in the manual?

Siemens SINAMICS S Series Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals