List of parameters
Parameters
1-341
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: Re bit 00:
Status to display the single initialization after POWER ON.
Re bit 01:
State in which the automatic restart function waits for faults (initial state).
Re bit 02:
General display that a fault has been identified and that the restart or acknowledgement has been initiated.
Re bit 03:
Displays the acknowledge command within the "acknowledge alarms" status (bit 4 = 1). For bit 5 = bit 6 = 1, the
acknowledge command is continually displayed.
Re bit 04:
State in which the faults that are present are acknowledged. The status is exited again after successful acknowl-
edgement. A change is only made into the next state if it is signaled that a fault is no longer present after an
acknowledgement command (bit 3 = 1).
Re bit 05:
State in which the drive is automatically powered-up (only for p1210 = 4, 6).
Re bit 06:
State in which the system waits after having been powered-up, to the end of the start attempt.
For p1210 = 1, this signal is directly set after the faults have been successfully acknowledged.
Re bit 07:
State, which is assumed after a fault occurs within the automatic restart function.
Re bits 12 ... 15:
Actual state of the start counter (binary coded).
Description: Automatic restart (AR) status word.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Initialization Yes No -
01 Wait for alarm Yes No -
02 Auto restart active Yes No -
03 Setting the acknowledgement command Yes No -
04 Acknowledge alarms Yes No -
05 Restart Yes No -
06 Delay time running after automatic power-
up
Yes No -
07 Fault Yes No -
12 Start count. bit 0 On Off -
13 Start count. bit 1 On Off -
14 Start count. bit 2 On Off -
15 Start count. bit 3 On Off -
r1214.0...15 CO/BO: Automatic restart, status / AR status
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Functions Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Initialization Yes No -
01 Wait for alarm Yes No -
02 Auto restart active Yes No -
03 Setting the acknowledgement command Yes No -
04 Acknowledge alarms Yes No -
05 Restart Yes No -
06 Delay time running after automatic power-
up
Yes No -
07 Fault Yes No -
12 Start count. bit 0 On Off -