Siemens SINAMICS S Series - r1732 CO: Direct-axis voltage setpoint; Direct V set; r1733 CO: Quadrature-axis voltage setpoint; Quad V set; p1740[0...n] Gain resonance damping for sensorless closed loop control; Gain res_damp; p1744[0...n] Motor model speed threshold stall detection; MotMod n_thr stall

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-471
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the direct-axis voltage setpoint Ud.
Description: Displays the quadrature-axis component of voltage setpoint Uq.
Description: Defines the gain of the controller for resonance damping for operation with sensorless vector control in the range
that current is impressed.
Description: Sets the speed threshold value to detect a stalled motor.
If the adaptation controller output exceeds the parameterized speed difference, then bit 11 in status word p1408 is
set.
Dependency: If a stalled drive is detected (p1408.11 set), fault 7902 is output after the delay time in p2178.
Refer to: p2178
Note: Speed monitoring is only effective in operation with a speed encoder (refer to p1300).
r1732 CO: Direct-axis voltage setpoint / Direct V set
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 5714,
6714, 5718
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1733 CO: Quadrature-axis voltage setpoint / Quad V set
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1630, 5714,
5718, 6714, 6719
P-Group: Closed-loop control Units group: 5_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
p1740[0...n] Gain resonance damping for sensorless closed loop control / Gain res_damp
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.000 10.000 0.025
p1744[0...n] Motor model speed threshold stall detection / MotMod n_thr stall
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.00 [RPM] 210000.00 [RPM] 100.00 [RPM]