EasyManua.ls Logo

Siemens SINAMICS S Series - p0300[0...n] Motor type selection; Mot type selection

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-130
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Selects the motor type or start to read-in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000).
The following applies for p0300 < 10000: The first digit of the parameter value always defines the general motor
type and corresponds to the unlisted motor belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
3 = Linear induction motor (reserved)
4 = Linear synchronous motor
The type information must be entered to filter motor-specific parameters and to optimize the operating characteris-
tics and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Values: 0: No motor
1: Induction motor (rotating)
2: Synchronous motor (rotating, permanent-magnet)
4: Synchronous motor (linear, permanent-magnet)
102: 1PH2 induction motor
104: 1PH4 induction motor
107: 1PH7 induction motor
134: 1PM4 induction motor
136: 1PM6 induction motor
166: 1PL6 induction motor
206: 1FT6 synchronous motor
207: 1FT7 synchronous motor
236: 1FK6 synchronous motor
237: 1FK7 synchronous motor
261: 1FE1 synchronous motor
276: 1FS6 synchronous motor
283: 1FW3 synchronous motor
286: 1FW6 synchronous motor
291: 2SP1 synchronous motor
401: 1FN1 synchronous motor (linear)
403: 1FN3 synchronous motor (linear)
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency: When the motor type is changed, the code number in p0301 may be reset to 0.
If p0300 is changed during quick commissioning (p0010 = 1), then the matching technological application (p0500) is
automatically pre-assigned. This does not occur when commissioning the motor (p0010 = 3). If 10000 is written to
p0300 for a parameter download, then p0500 is pre-assigned with Drive-CLiQ corresponding to the motor type.
Refer to: p0301
Caution: If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters,
that are associated if this list, cannot be changed (write protection). The write protection is canceled if the motor
type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx).
Notice: The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note: With p0300 = 10000, for a motor with DRIVE-CLiQ, the motor parameters are automatically downloaded, with
p0300 = 10001, the motor parameters of a second data set (if available).
If a motor type has not been selected (p0300 = 0), then the drive commissioning routine cannot be exited.
A motor type with a value above p0300 >= 100 describes motors for which a motor parameter list exists.
Motor types with a value below p0300 < 100 correspond to the selection of an unlisted motor. When appropriately
selected, this means that the motor parameters are pre-assigned the settings for an unlisted motor.
p0300[0...n] Motor type selection / Mot type selection
SERVO Can be changed: C2(1, 3) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: 6310
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 10001 0

Table of Contents