Siemens SINAMICS S Series - r1114 CO: Setpoint after the direction of rotation limit; Setp after limit; r1114 CO: Setpoint after the direction limiting; Setp after limit; p1115 Ramp-function generator selection; RFG selection; r1119 CO: Ramp-function generator setpoint at the input; RFG setp at inp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-318
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the speed/velocity setpoint after the changeover and limiting the direction.
Description: Displays the speed/velocity setpoint after the changeover and limiting the direction.
Description: Sets the ramp-function generator type.
Values: 0: Single ramp-function generator
1: Extended ramp-function generator
Note: Another ramp-function generator type can only be selected when the motor is at a standstill.
Description: Displays the setpoint at the input of the ramp-function generator.
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: The setpoint is influenced by other functions, e.g. skip (suppressed) speeds, minimum and maximum limits.
r1114 CO: Setpoint after the direction of rotation limit / Setp after limit
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3040,
3050
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1114 CO: Setpoint after the direction limiting / Setp after limit
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3040,
3050
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]
p1115 Ramp-function generator selection / RFG selection
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: 1550, 3080
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 0
r1119 CO: Ramp-function generator setpoint at the input / RFG setp at inp
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 1750,
3050, 3060, 3070, 8010
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]