Parameters
List of parameters
1-466
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the current setpoint filter 4 as low pass (PT2) or as extended general 2nd-order filter.
Values: 1: Low pass: PT2
2: General 2nd-order filter
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
p1672[0...n] Current setpoint filter 4 type / I_set_filt 4 Typ
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 2 1
p1673[0...n] Current setpoint filter 4 denominator natural frequency / I_set_filt 4 fn_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1674[0...n] Current setpoint filter 4 denominator damping / I_set_filt 4 D_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1675[0...n] Current setpoint filter 4 numerator natural frequency / I_set_filt 4 fn_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]