Siemens SINAMICS S Series - p1672[0...n] Current setpoint filter 4 type; I_set_filt 4 Typ; p1673[0...n] Current setpoint filter 4 denominator natural frequency; I_set_filt 4 fn_n; p1674[0...n] Current setpoint filter 4 denominator damping; I_set_filt 4 D_n; p1675[0...n] Current setpoint filter 4 numerator natural frequency; I_set_filt 4 fn_n

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-466
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the current setpoint filter 4 as low pass (PT2) or as extended general 2nd-order filter.
Values: 1: Low pass: PT2
2: General 2nd-order filter
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: The current setpoint filters are parameterized with p1656 to p1676.
p1672[0...n] Current setpoint filter 4 type / I_set_filt 4 Typ
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 2 1
p1673[0...n] Current setpoint filter 4 denominator natural frequency / I_set_filt 4 fn_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1674[0...n] Current setpoint filter 4 denominator damping / I_set_filt 4 D_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700
p1675[0...n] Current setpoint filter 4 numerator natural frequency / I_set_filt 4 fn_n
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5710
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]