Siemens SINAMICS S Series - p1551[0...n] BI: Torque limit variable;fixed signal source; M_lim var;fixS_src; p1551[0...n] BI: Force limit variable;fixed signal source; F_lim var;fixS_src; p1552[0...n] CI: Torque limit upper scaling without offset; M_max up offs scal; p1552[0...n] CI: Force limit upper scaling without offset; F_max up offs scal

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-444
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to change over the torque limits between variable and fixed torque limit.
1 signal from BI: p1551:
The variable torque limit applies (fixed torque limit + scaling).
0 signal from BI: p1551:
The fixed torque limit applies.
Example:
In order that for a Quick Stop (OFF3) the fixed torque limit is effective, BI: p1551 must be interconnected to r0899.5.
Description: Sets the signal source to change over the force limits between variable and fixed force limit.
1 signal from BI: p1551:
The variable force limit applies (fixed force limit + scaling).
0 signal from BI: p1551:
The fixed force limit applies.
Example:
In order that for a Quick Stop (OFF3) the fixed force limit is effective, BI: p1551 must be interconnected to r0899.5.
Description: Sets the signal source for the scaling of the upper torque limiting to limit the speed controller output without taking
into account the current and power limits.
Description: Sets the signal source for the scaling of the upper force limiting to limit the velocity controller output without taking
into account the current and power limits.
p1551[0...n] BI: Torque limit variable/fixed signal source / M_lim var/fixS_src
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 5620, 5630,
6060, 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1551[0...n] BI: Force limit variable/fixed signal source / F_lim var/fixS_src
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 5620, 5630,
6060, 6630
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1552[0...n] CI: Torque limit upper scaling without offset / M_max up offs scal
SERVO, VECTOR
(n/M)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1
p1552[0...n] CI: Force limit upper scaling without offset / F_max up offs scal
SERVO (Lin) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 6060
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 1