EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-129 3618 - Direct setpoint input;MDI mode, dynamic values (r0108.4 = 1)

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Basic positioner (EPOS)
2-1244
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-129 3618 – Direct setpoint input/MDI mode, dynamic values (r0108.4 = 1)
- 3618 -
Function diagram
87654321
fp_3618_01_eng.vsd
DO: SERVO, VECTOR
SINAMICS S
07.05.07 V02.05.00
EPOS - Direct setpoint input/MDI mode, dynamic values (r0108.4 = 1)
[3620.1]
p0115[5]
Pos fixed value
-2147483648...2147483647 [LU]
p2690 (0)
p2690
v fixed value
1...2147483647 [1000 LU/min]
p2691 (600)
p2691
a_over fixed value
0.100...100.000 [%]
p2692 (100.000)
p2692
-a_over fixed value
0.100...100.000 [%]
p2693 (100.000)
p2693
[3620.1]
[3620.1]
[3620.1]
MDI s_set
(p2690)
p2642
MDI -a_over
(p2693)
p2645
MDI a_over
(p2692)
p2644
MDI v_set
(p2691)
p2643
100 %
0.1 %
100 %
0.1 %
1

Table of Contents