Siemens SINAMICS S Series - p1755[0...n] Motor model changeover velocity sensorless operation; MotMod v_chgSnsorl; p1755[0...n] Motor model changeover speed sensorless operation; MotMod n_chgSnsorl; p1756 Motor model changeover speed hysteresis; MotMod n_chgov hys; p1756 Motor model changeover velocity hysteresis; MotMod v_chgov hys

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-475
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the velocity to change over the motor model to sensorless operation (without encoder).
Dependency: Refer to: p1756
Note: The changeover velocity applies for the changeover between open-loop and closed-loop control mode.
Description: Sets the speed to change over the motor model to sensorless operation (without encoder).
Dependency: Refer to: p1756
Notice: The changeover speed represents the steady-state minimum speed up to which the motor model can be used
in steady-state operation without encoder (sensorless operation).
If the stability is not adequate close to the changeover speed, it may make sense to increase the parameter value.
Note: The changeover speed applies for the changeover between open-loop and closed-loop control mode.
Description: Sets the hysteresis for the changeover speed/velocity of the motor model.
Dependency: Refer to: p1752, p1755
Note: The value is entered relative to p1404, p1752 or p1755.
Description: Sets the hysteresis for the changeover speed/velocity of the motor model.
Dependency: Refer to: p1752, p1755
Note: The value is entered relative to p1404, p1752 or p1755.
p1755[0...n] Motor model changeover velocity sensorless operation / MotMod v_chgSnsorl
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [m/min] 1000.0 [m/min] 1000.0 [m/min]
p1755[0...n] Motor model changeover speed sensorless operation / MotMod n_chgSnsorl
VECTOR Can be changed: U, T Calculated: CALC_MOD_REG Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL, FEM Expert list: 1
Min Max Factory setting
0.0 [RPM] 210000.0 [RPM] 210000.0 [RPM]
p1756 Motor model changeover speed hysteresis / MotMod n_chgov hys
SERVO Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 90.0 [%] 5.0 [%]
p1756 Motor model changeover velocity hysteresis / MotMod v_chgov hys
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 90.0 [%] 5.0 [%]